Franklin Electric Turf Boss 3–5 HP Self-Priming Pumps

Turf Boss Self-Priming Centrifugal Pump
Supplying Water Pump Parts Since 1991
Shipping Across the U.S. & Canada
Same-Day Shipping on Eligible Orders

Turf Boss 3–5 HP Pump Manuals & Repair Resources

Franklin Electric Turf Boss 3–5 HP self-priming centrifugal pumps are designed for larger timer-operated sprinkler, golf-course, municipal turf, and commercial irrigation applications. The series includes 3 HP and 5 HP motor-driven models, including single-phase, three-phase, ODP, and TEFC motor configurations. Built-in suction check valves help retain priming water between normal operating cycles.

For a smaller lawn or irrigation installation, see the Turf Boss 1–2 HP pumps. Those models have a different 56J motor-frame arrangement and 1½-inch suction/discharge connections.

Compare the linked order numbers, performance information, exploded view, replacement motor references, and service parts below before choosing a complete pump or pump-end kit.

Why Choose the 3–5 HP Turf Boss Series?

  • Self-priming sprinkler service: designed for timer-operated irrigation, with an integral suction check valve to reduce backflow and help retain priming water.
  • Commercial pump construction: cast iron volute, cast iron diffuser, and mechanical shaft seal with carbon/ceramic faces and FKM elastomers.
  • 3 HP and 5 HP choices: 3 HP uses 2-inch suction and discharge; 5 HP uses a 2½-inch suction and 2-inch discharge.
  • JM-frame motors: complete pumps in single-phase and three-phase versions; ODP and TEFC enclosure options, including selected 575 V three-phase models.
  • Service access: replacement impellers, check-valve components, gaskets, seals, motors and pump-end kits identifiable by model and figure number.

Turf Boss 3–5 HP Technical Specifications

Specification Value
Maximum Flow Rate 160 GPM
Maximum Head 170 feet
Maximum Working Pressure 75 PSI
Maximum Water Temperature 120 degrees F
Pipe Connections NPT
Rotation Clockwise viewed from motor end
Impeller Material 304 stainless steel in current manufacturer model listings; confirm replacement part by exact pump model
Pump Case Material Cast iron, ASTM-A48 CL30
Seal Type Carbon/ceramic faces, FKM elastomers, stainless steel components
Motor Frame Standard JM frame

The series is advertised for up to 160 GPM and 170 feet of head, with a 75 PSI working-pressure limit and a 120°F water-temperature limit. These are separate rating limits, not a single duty point. Use the model performance table and confirm suction-lift conditions for system sizing.

3 HP vs. 5 HP: Connection and Motor Differences

Choose 3 HP for a 2-inch by 2-inch NPT pump and 5 HP for a 2½-inch suction by 2-inch discharge pump when the performance curve shows the required flow at your intended operating pressure. The 3 HP single-phase models are listed as 115/230 V; the 5 HP single-phase models use 230 V. Verify all three-phase voltage and enclosure options by item number.

Turf Boss 3–5 HP Ordering Information: All 10 Motor-Driven Configurations

All ten original pump ordering rows are retained below, with their motor codes, phase, voltage, service-factor amps, frame sizes and shipping weights. Each order number links to its corresponding individual product page.

HP Pump Size (Suc. x Dis.) ECNL Phase Volts SFA Motor Frame Size Motor Code Model Order No. Wt. (lbs)
3 2″ x 2″ ODP 1 115/230 33.4/16.7 182JM JM-1 FTB3CI 92980030 134
3 230/460 8.4/4.2 145JM JM-1 FTB3CI-T 92980035 110
TEFC 1 115/230 33.4/16.7 182JM JM-1 FTB3CI-E 92980130 134
3 230/460 8.2/4.1 145JM JM-1 FTB3CI-TE 92980135 110
3 575 3.3 145JM JM-1 FTB3CI-T5E 92980136 106
5 2½” x 2″ ODP 1 230 25.3 184JM JM-1 FTB5CI 92980050 140
3 230/460 13.8/6.9 182JM JM-1 FTB5CI-T 92980055 130
TEFC 1 230 19.0 184JM JM-1 FTB5CI-E 92980150 140
3 230/460 13.4/6.7 184JM JM-1 FTB5CI-TE 92980155 130
3 575 5.4 184JM JM-1 FTB5CI-T5E 92980156 125

Turf Boss 3–5 HP Pump-End Kits (Without Motors)

The 3 HP pump-end kit is FTB3CI-PE (92980033) and the 5 HP pump-end kit is FTB5CI-PE (92980053). These are not complete motor-powered pumps. Confirm the matching JM motor frame, coupling/shaft fit and available motor horsepower/service factor before ordering.

HP Pump Size (Suc. x Dis.) NEMA Mtr Frame Size Fitment Model Order No. Wt. (lbs)
3 2″ x 2″ 143-184JM 4.5 AK 0.875″ Shaft FTB3CI-PE 92980033 60
5 2-1/2″ x 2″ FTB5CI-PE 92980053

Exploded Parts and Repair-Part Numbers: 3 HP vs. 5 HP

The original parts matrix is retained, including separate 3 HP and 5 HP impellers, shaft keys, check valves, impeller washers and motor-adapter fasteners. Use the exploded diagram figure number and exact pump model to select the right part.

Franklin Electric Turf Boss 3 to 5 HP exploded pump parts diagram
Fig. No. Part Description Part No. Materials of Construction
3 HP 5 HP 3 HP 5 HP
1 Pump Case 305461011 Cast iron, ASTM-A48 CL30
2 Impeller 305453025 305453026 Cast iron, ASTM-A48 CL30 304 Stainless steel
3 Motor Adapter 305461012 Cast iron, ASTM-A48 CL30
12 Mechanical Seal Shaft Sleeve 305458011 416 Stainless steel
35 Shaft Key 305453028 305451003 301 Stainless steel
72 Check Valve 305455010 305460018 Cast iron, ASTM-A48 CL30
73A Top Weight, Check Valve 305455011 Cast iron, ASTM-A48 CL30
73B Bottom Weight, Check Valve 305455012 Cast iron, ASTM-A48 CL30
74 Diffuser 305460019 Cast iron, ASTM-A48 CL30
90 Mechanical Shaft Seal 305457011 Carbon/ceramic x FKM/stainless steel
100A Case Gasket 305461013 Nitrile
100B Flapper Valve 305454043 Neoprene
100C Square-Ring, Volute 305463131 Nitrile
200 Motor See Motor section Misc.
500 Pipe Plug, 3/4″ (2 req.) 305463050 CAD-plated steel
503 Water Slinger 305453030 Neoprene
510 Bolt, Impeller 305461014 416 Stainless steel
520 Washer, Impeller 305448013 305455014 417 Stainless steel
530A Nut, Flapper 305463082 300 Stainless steel
530B Washer, Flapper 305463084 300 Stainless steel
530C Bolt, Flapper 305463080 316 Stainless steel
530D Hex Bolts, Volute (8 pack) 305463064 Zinc-plated steel
530E Hex Bolt, Motor Adapter (4 req.) 305463120 305463121 Zinc-plated steel
530G Hex Bolt, Check Valve 305463010 Zinc-plated steel

Impeller-material identification: Franklin’s current product listings describe 304 stainless-steel impellers for 3 HP and 5 HP motor-driven Turf Boss models. Older published parts breakdowns label figure 2 material differently, while using part 305453025 (3 HP) and 305453026 (5 HP). Confirm the actual pump build and replacement part with Franklin or Kendisco before purchase. The original reference numbers are retained above.

Replacement Motors: Frame, Voltage and Motor Number

Use the original motor cross-reference to identify the correct ODP or TEFC motor. The listed HP, phase, voltage, 3600 RPM speed, service factor, SFA, JM frame and motor number vary by model. Motor replacement requires verification against the motor nameplate and the pump-end assembly.

RPM ENCL PH Volts HP Mtr S.F. SFA Frame Motor Code Motor Number Wgt. Lbs.
3600 ODP 1 115/230 3 1.15 33.4/16.7 182JM JM-1 305374930 70
230 5 1.15 25.3 184JM JM-1 305374931 78
3 230/460 3 1.15 8.4/4.2 145JM JM-1 104236202 49
5 1.15 13.8/6.9 182JM JM-1 104236204 64
TEFC 1 115/230 3 1.15 33.4/16.7 182JM JM-1 107026029 79
230 5 1.15 19.0 184JM JM-1 104220002 93
3 230/460 3 1.15 8.2/4.1 145JM JM-1 104238202 54
5 1.15 13.4/6.7 184JM JM-1 104238204 79
575 3 1.15 3.3 145JM JM-1 104224201 50
5 1.15 5.4 184JM JM-1 104224202 74

Dimensions for 3 HP and 5 HP Turf Boss Pumps

Franklin Electric Turf Boss 3 to 5 HP overall dimensions and motor envelope drawing
Model Enclosure Pump Size (SUC. X DIS) Dimensions (in.)
A B D E F H AB BA OP
FTB3CI ODP 2″ X 2″ 8.63 6.50 4.50 3.75 5.50 0.41 6.75 3.50 23.78
FTB3CI-E TEFC 2″ X 2″ 8.63 6.50 4.50 3.75 5.50 0.44 6.87 3.50 29.59
FTB3CI-T ODP 2″ X 2″ 6.50 5.94 3.50 2.75 5.00 0.34 5.62 2.88 22.41
FTB3CI-TE TEFC 2″ X 2″ 6.50 5.94 3.50 2.75 5.00 0.38 5.74 2.88 23.57
FTB3CI-T5E TEFC 2″ X 2″ 6.50 5.94 3.50 2.75 5.00 0.38 5.74 2.88 23.57
FTB5CI ODP 2 1/2″ X 2″ 8.63 6.50 4.50 3.75 5.50 0.41 6.75 3.51 23.78
FTB5CI-E TEFC 2 1/2″ X 2″ 8.63 6.50 4.50 3.75 5.50 0.45 6.87 3.50 26.83
FTB5CI-T ODP 2 1/2″ X 2″ 8.63 6.50 4.50 3.75 5.50 0.41 6.74 3.50 23.78
FTB5CI-TE TEFC 2 1/2″ X 2″ 8.63 6.50 4.50 3.75 5.50 0.41 6.87 3.50 25.34
FTB5CI-T5E TEFC 2 1/2″ X 2″ 8.63 6.50 4.50 3.75 5.50 0.41 6.87 3.50 25.34

Turf Boss 3–5 HP Performance Graph and Flow Table

Read the GPM flow data against both total suction lift and the discharge pressure shown. The 3 HP and 5 HP operating curves differ; published maxima should never replace a curve-based selection for a specific duty point.

Franklin Electric Turf Boss 3 to 5 HP pressure and GPM performance graph
Model HP Total Suction Lift (ft) Discharge Pressure (PSI) Shut-off Pressure (PSI)
25 30 35 40 45 50 55 60 65
Gallons Per Minute (GPM)
FTB3CI 3 5 99 90 81 70 60 47 – – – 56
10 95 86 77 66 54 – – – – 54
15 91 82 73 62 49 – – – – 51
20 87 78 68 56 42 – – – – 49
25 84 74 63 51 – – – – – 47
FTB5CI 5 5 149 141 131 122 112 102 89 74 55 71
10 146 137 127 118 108 97 82 65 – 69
15 142 132 124 114 104 92 76 57 – 67
20 138 129 119 109 98 84 68 – – 65
25 134 125 116 105 92 78 60 – – 63

JM Motor Fit Code

Motor Fit Code Flange Rabbet, AK Shaft End Diameter, U Shaft Length Fits Motor Frame
JM-1 4.5 0.875” 4.25” 143-145-182-184

Applications and Installation Considerations

  • Commercial turf and golf-course irrigation: larger multi-zone sprinkler and landscape systems requiring 3 or 5 HP pump duty.
  • Municipal and light-industrial clean-water transfer: water movement within the pump’s flow, head, temperature and material limitations.
  • Initial priming: fill the pump case before initial startup and follow the owner’s manual for suction piping, check-valve service and air-tight connections.
  • Fluid suitability: manufacturer states this series is not intended for solids or abrasive fluids; avoid sand-laden or slurry dewatering.
  • Voltage, phase and enclosure: verify the exact model, operating power and motor enclosure; weather exposure must be evaluated separately from the pump’s indoor/outdoor certification.
  • Winterizing and service: drain water when freezing is possible and use the exact figure numbers above for check-valve, seal and impeller work.

Turf Boss 3–5 HP vs. 1–2 HP Models

For smaller timer-operated irrigation systems, the Turf Boss 1–2 HP range offers 1½-inch threaded inlet/outlet connections, 56J-frame motors, and models with Modified PPO or stainless-steel impellers. The 3–5 HP pumps on this page have larger connections, a built-in suction check valve and JM-frame motors. Both model groups should be sized from their individual performance curves rather than a single family maximum.

Frequently Asked Questions

What is the difference between the 3 HP and 5 HP Turf Boss pumps?

The 3 HP pump uses 2-inch suction and discharge connections. The 5 HP pump has 2½-inch suction and 2-inch discharge. Motor options, flow curves, parts and shipping weights also differ by item number.

Does the Turf Boss 3–5 HP series have a built-in check valve?

Yes. Franklin specifies a check valve within the volute to help retain prime and reduce reverse flow or siphoning after shutdown. The pump casing still requires proper initial priming.

What impeller material is used in the 3 HP model?

Franklin’s current 3 HP product listings identify stainless steel. Some older repair-parts references describe material differently, so identify the exact model and repair part number before ordering a replacement impeller.

Can I buy the 3–5 HP pump end without a motor?

Yes. Model FTB3CI-PE uses order number 92980033, and model FTB5CI-PE uses 92980053. These units do not include a motor and need a compatible JM-frame driver.

Can I get ODP and TEFC versions?

Yes, both 3 HP and 5 HP model families list ODP and TEFC configurations. Match the electrical supply, phase, motor frame and enclosure to the exact model, as not every option is identical.

Which repair parts are available?

The exploded parts matrix identifies pump cases, separate impellers, seals, gaskets, flapper and check-valve parts, diffusers, hardware, and motor references by figure number and horsepower.

Can Turf Boss handle gritty water or sand?

No. Franklin notes that Turf Boss pumps are not intended for abrasive fluids or solids-bearing water.

Request a Turf Boss 3–5 HP Pump or Repair-Part Quote

Ken’s Distributing Company can help cross-check an existing Turf Boss nameplate, motor configuration, or repair part number. Contact Kendisco for pricing and availability or call 303-699-7845. Request confirmation of stock and delivery timing for your exact item.

Related Products

Send us your model number and we will confirm fit, price, and availability.

Products Form