Franklin Electric End Gun Booster Pump, 2 HP, 460V

Franklin Electric End Gun Booster Pump with cast iron casing and stainless steel impeller.
Supplying Water Pump Parts Since 1991
Shipping Across the U.S. & Canada
Same-Day Shipping on Eligible Orders

End Gun Booster Pump Manuals & Resources

The Franklin Electric End Gun Booster Pump adds pressure for an end gun sprinkler on a center pivot irrigation system. This 2 HP, 460V, three-phase pump is available as the complete FEGB-200TE or the FEGBLV-200TE less-volute replacement assembly for a compatible existing casing. Compare the models, specifications and selected repair parts below, then send Ken’s Distributing your existing pump model and end gun operating requirements for a price and availability quote.

Franklin Electric End Gun Booster Pump Specifications

Specification FEGB Series details
Pump application Center pivot irrigation end gun pressure boosting
Models FEGB-200TE (complete pump); FEGBLV-200TE (less volute)
Motor 2 HP, 460 VAC, 3-phase, 60 Hz, nominal 3600 RPM, 2-pole
Motor enclosure TEFC (totally enclosed fan cooled); 1.50 service factor listed in series data
Hydraulic design Single-stage centrifugal, enclosed stainless steel impeller
Impeller diameter 4.5 in.
Complete pump casing Cast iron, back pull-out service design
Suction connection 2.5 in. FNPT
Discharge connection 2 in. FNPT
Shaft seal Mechanical seal; carbon/ceramic faces and nitrile elastomers listed in series description
Mounting Horizontal or vertical as permitted by the pump and motor installation instructions
Maximum listed liquid temperature 212°F (100°C); confirm operating conditions and seal suitability
Pump selection Required end gun GPM and pressure boost at the actual pivot operating point

Before ordering: Confirm that the site has a suitable 460V three-phase supply, and check the existing casing, pipe orientation and duty point. The pump’s motor horsepower alone does not establish how much additional pressure it will provide at the end gun’s required flow.

FEGB-200TE vs. FEGBLV-200TE: Order the Right End Gun Booster

Choose a complete pump when the casing must also be replaced or for a compatible new installation. Choose the less-volute model when the existing volute can be retained and the replacement rotating assembly fits it. Both options require a model and dimensional check before a retrofit.

Item number Model Configuration Motor Approx. product weight When to consider
71250245101 FEGB-200TE Complete pump with cast iron volute 2 HP, 460V, 3-phase TEFC 72 lb New installation or complete replacement
63250245201 FEGBLV-200TE Less-volute pump assembly 2 HP, 460V, 3-phase TEFC 65 lb Replacing a compatible motor and pump-end assembly while retaining the existing volute

Request a complete pump or less-volute quote: Send Ken’s Distributing the model and item number, the existing pump brand and model, and photographs or measurements of the volute and mounting arrangement. Ask for FEGB pump pricing and availability. For a retrofit, include the existing casing’s condition and connection sizes.

How a Center Pivot End Gun Booster Pump Works

An end gun extends sprinkler coverage beyond the end of a center pivot. It may need more pressure than is available at the outer end of the pivot, particularly after friction and elevation losses along the system. An end gun booster draws from the pivot’s water supply and raises the pressure delivered to the end gun while that zone is operating.

The FEGB is a centrifugal pressure booster, not a substitute for designing the end gun, pipework and controls as a system. The selected pump must produce the required added head at the end gun’s actual operating GPM. Mounting location, pipe losses and available inlet pressure all affect the result.

How to Size the FEGB Booster for End Gun Flow and Pressure

For an accurate selection, compare the end gun manufacturer’s pressure requirement with measured or calculated pressure at the booster inlet while the pivot is operating. Also account for piping losses between the booster discharge and the sprinkler.

Buyer information Why it matters
End gun make, model and nozzle Establishes the manufacturer’s flow and operating pressure requirements
Required end gun flow, GPM Determines the duty point at which the booster must add head
Pressure available at the booster inlet Shows how much pressure is already provided by the pivot system
Target pressure at the end gun Defines the remaining boost requirement after discharge-line losses
Existing pump and volute dimensions Helps check fit of a complete pump or FEGBLV less-volute retrofit
460V, three-phase power and controls Confirms motor compatibility and how the booster starts with the end gun

The FEGB performance must be checked on its own pump curve; a generic pressure range for end gun sprinklers does not establish this model’s suitability. Use the Performance Curves resource above when selecting the pump.

Features That Matter on a Pivot Irrigation Booster

  • Cast iron back pull-out casing: Provides service access to the rotating assembly on compatible installations while leaving the casing connected to the piping.
  • Enclosed stainless steel impeller: A corrosion-resistant hydraulic component intended for the end gun pressure-boosting application.
  • 2 HP, 460V three-phase TEFC motor: Designed for the specified electrical service, with a fan-cooled enclosed motor housing.
  • Mechanical shaft seal: Enables pump-end service when wear or leakage develops, using model-matched replacement components.
  • Less-volute replacement choice: Offers an alternative to replacing the entire casing when an existing volute is compatible and serviceable.
  • 2.5-inch suction and 2-inch discharge: Helps buyers confirm piping and retrofit compatibility before requesting a quote.

The series describes a 1.50 motor service factor, but that figure is not a reason to operate the pump continuously beyond its application limits. Use the motor nameplate, pump curve and installation instructions for the allowable operating conditions.

Franklin Electric End Gun Booster Replacement Parts

Ken’s Distributing also handles quote requests for FEGB end gun booster pump replacement parts. A failed impeller, worn hardware or damaged volute does not necessarily require replacing the entire pump. Identify the component from the model and repair-parts diagram, then confirm the replacement number before ordering.

Repair part Listed part number What to check
Volute with plugs 305462047 Condition of the existing casting and port arrangement
Impeller kit 305462048 Impeller wear and the exact pump assembly
Motor bracket 305462049 Bracket damage and motor mounting fit
Studs, four-pack 305462224 Hardware condition and pack quantity
Motor bracket bolts 305462051 Correct replacement hardware

These are selected references from the FEGB repair-parts breakdown available in the resource buttons above. If you need a mechanical seal, motor or an unlisted component, send the model and motor nameplate details so the correct current part number can be checked. Do not assume a similarly sized end gun booster uses interchangeable parts.

Request a parts quote: Include FEGB-200TE or FEGBLV-200TE, any number from the table, the quantity, and a photo of the nameplate or failed component. Ken’s Distributing can check fit, pricing and availability before you order.

Complete Pump, Less-Volute Assembly or Repair Part?

Situation Practical starting point
New center pivot booster or a cracked/unsuitable casing Quote FEGB-200TE complete pump, subject to hydraulic and dimensional fit
Motor or rotating assembly failed; existing casing is in good condition Check FEGBLV-200TE less-volute replacement compatibility
Impeller or replaceable hardware worn Identify the corresponding FEGB repair part number
Reduced end gun reach with an otherwise operating pump Check inlet pressure, system flow, end gun nozzle, controls and pump curve before replacing equipment

Installation and Service Considerations

  • Electrical supply: Confirm 460V three-phase service, motor protection and a compatible end gun control sequence with a qualified installer.
  • Water supply: Make sure water is present before the booster runs; the pump’s mechanical seal needs water during normal operation.
  • Pipe connection and orientation: Confirm the 2.5-inch FNPT suction, 2-inch FNPT discharge, and required motor and piping clearances.
  • Retrofit fit: For the less-volute version, match the existing casing and mounting interface rather than relying only on the motor horsepower.
  • Service access: Allow clearance for back pull-out maintenance and follow the manufacturer’s installation instructions.

For an existing pivot, refer to the Dimensions resource above when comparing the replacement assembly with your current installation.

Frequently Asked Questions About End Gun Booster Pumps

What does an end gun booster pump do on a center pivot?

It adds pressure to the water supplied to the end gun sprinkler so the end gun can operate at its intended flow and pressure when the pivot is watering the outer coverage area.

What is the difference between FEGB-200TE and FEGBLV-200TE?

FEGB-200TE is a complete pump with its cast iron volute. FEGBLV-200TE is the less-volute replacement assembly intended for a compatible existing volute. Both listed models have a 2 HP, 460V three-phase motor.

What are the Franklin Electric end gun booster pump item numbers?

The complete pump is item 71250245101, model FEGB-200TE. The less-volute unit is item 63250245201, model FEGBLV-200TE. The table near the top provides individual product links.

Does the FEGB end gun booster require 460V three-phase power?

Yes. Both listed versions have a 2 HP, 460V, 60 Hz three-phase TEFC motor. Confirm that supply is available where the booster will be installed.

What are the suction and discharge sizes?

The listed complete pump has a 2.5-inch FNPT suction connection and a 2-inch FNPT discharge connection. Confirm the existing casing arrangement before ordering a less-volute replacement.

How much pressure boost will a 2 HP FEGB provide?

The boost depends on the water flow through the pump and the operating point shown on the FEGB performance curve. Provide the required end gun GPM, inlet pressure and target pressure to check whether this pump fits the duty.

Can I buy an FEGB impeller kit instead of replacing the pump?

The listed impeller kit is 305462048. The casing, motor and other components should be inspected so you can choose repair or replacement based on the condition of the complete assembly.

Can Ken’s Distributing quote complete pumps and individual repair parts?

Yes. Send the full FEGB model, item number or part reference along with the application details. Ken’s Distributing can confirm compatible options, current pricing and availability for either a complete booster or a replacement component.

Request Franklin Electric FEGB Pump or Repair Parts Pricing

Ken’s Distributing supplies water pumps and replacement parts to buyers across the United States and Canada. For a faster FEGB quote, share whether you need the complete FEGB-200TE, the FEGBLV-200TE less-volute unit, or a specific repair part. Include your existing pump model, end gun nozzle/flow requirement, available inlet pressure, required pressure at the gun, 460V supply details and delivery location.

Contact Ken’s Distributing with your pump or part number and installation details to confirm fit, price and availability.

Send us your model number and we will confirm fit, price, and availability.

Products Form