Franklin Electric Centrifugal Self priming Frame Mount FTT 20 – 40

Monarch TT-60 to Franklin FTT-40: The Swap

Products Form

Get a Fast Quote from a Pump Specialist

A TT-60 that needs a part is a problem with only one real answer, because the parts stopped being made. The pump still runs until the day it does not.

Planning that changeover before it becomes an emergency is the difference between an afternoon and a week of downtime.

What Replaced the Monarch TT-60?

The Franklin Electric FTT-40 self priming frame mount pump is the usual replacement for a discontinued Monarch TT-60. It is a slightly smaller pump, which suits the many installations that never used the TT-60’s full capacity, and coupler adapters bridge the different port sizes.

Key Takeaways

  • TT-60 repair parts are no longer available.
  • The FTT-40 is the usual replacement, at slightly lower capacity.
  • Coupler adapters avoid re-piping the installation.
  • Compare the two at your real duty point, not by model number.
  • Other Monarch series are still supported, only the TT-60 is obsolete.

How the Two Compare

Monarch TT-60 Franklin Electric FTT-40
Status Discontinued Current
Repair parts Not available Stocked
Capacity Higher Slightly lower
Maximum head Higher Slightly lower
Footprint Larger More compact
Port sizes Original Adapters usually needed

The capacity row is the only one that needs thinking about. Everything else on this list favors the newer pump, but a TT-60 that was genuinely running near its limit is not a straight swap.

Checking the Duty Point First

Model numbers do not decide whether a replacement performs the same. Flow and head at your actual operating conditions do, and those live on the pump curve rather than in a catalog description.

Find the flow you need and the total head the system imposes, then read what each pump delivers at that point, as covered in our guide to reading a pump curve. Both are self priming centrifugals, and the operating principle behind them is described in this reference on the centrifugal pump.

Why Coupler Adapters Matter

  • No re-piping, so existing suction and discharge lines stay.
  • Shorter downtime, measured in hours rather than days.
  • Lower labor cost than modifying the installation.
  • Reversible, since nothing permanent is cut.
  • Keeps line sizes, protecting the suction margin.

That last point is worth respecting. Reducing a suction line to match a smaller port is a false economy, because starving the pump on the suction side produces the damage described in our pump cavitation guide.

Why the TT-60 Went Away

The Monarch pump line passed to Franklin Electric in 2007, and models have been folded into Franklin’s own series gradually since then. The TT-60 is one that reached the end of that road rather than being carried across.

That history is set out in our guide to Monarch and Franklin Electric. It is worth knowing because a Monarch pump being old does not mean it is unsupported, and many series still have parts available, as our Monarch repair parts guide explains.

Trash Pump Duty

Both of these are trash pumps, built with wide internal clearances to pass solids that would jam a clean water pump. Replacing one with a general purpose centrifugal because the curve looks similar is a mistake that shows up the first time the pump sees site water.

What that duty actually demands is covered in our trash pump guide, and the wear components on any centrifugal are in our water pump parts guide.

Frequently Asked Questions

What replaced the Monarch TT-60?

The Monarch TT-60 was replaced by the Franklin Electric FTT-40, a self priming frame mount pump that serves the same trash pump duty at slightly lower capacity. That suits the many installations which never used the TT-60’s full output. Coupler adapters bridge the different suction and discharge port sizes so the existing pipework can stay in place.

Are Monarch TT-60 parts still available?

Monarch TT-60 parts are no longer available, and that is what drives most of these changeovers rather than any fault with the pump itself. Other Monarch series are still supported under Franklin Electric, so a TT-60 being obsolete does not mean the whole Monarch line is. Check the model before assuming a pump is unsupported.

Do you need adapters to fit an FTT-40 in place of a TT-60?

Adapters are normally needed to fit an FTT-40 in place of a TT-60, because the two pumps use different suction and discharge port sizes. Coupler adapters connect the existing pipework to the new pump without re-piping the system, which is what keeps the changeover to a short job rather than a rebuild of the whole installation.

Will an FTT-40 match the TT-60’s performance?

An FTT-40 is designed for slightly lower maximum head and pressure than a TT-60, so it matches on medium duty work and falls short where the old pump was genuinely working at its limit. Compare the two at your actual duty point on the pump curve before committing to the swap.

FTT-40 Pumps at Ken’s Distributing

Ken’s Distributing supplies the FTT-40 and coupler adapters across the Franklin Electric range, alongside remaining stock for the Monarch water pump range.

Send us the duty your TT-60 was actually doing, along with the suction and discharge line sizes, and we will confirm the FTT-40 covers it and specify the adapters before anything ships.