Franklin Electric FNSGF Gas Engine Self-Priming Pump & Parts

Franklin Electric FNSGF Gas Engine Self-Priming Pump
Supplying Water Pump Parts Since 1991
Shipping Across the U.S. & Canada
Same-Day Shipping on Eligible Orders

FNSGF Pump Manuals & Repair Resources

The Franklin Electric FNSGF Series gas engine-driven self-priming pump is built for water transfer and temporary irrigation when a portable pump must deliver reliable flow and pressure without an electrical supply. Its enclosed cast iron impeller, diffuser and self-priming arrangement make the series suitable for applications involving relatively clean water, including irrigation, construction and commercial water transfer.

The current Franklin Electric ordering catalog lists two Honda-powered FNSGF configurations: FNSGF-5H (item 90272105) and FNSGF-8H (item 90272108). This page also retains earlier Briggs & Stratton, diesel FNSDF, engine and repair-part references to help identify existing equipment. Contact Ken’s Distributing Company to confirm a specific model, engine or replacement part before placing an order.

Franklin Electric FNSGF Pump Specifications

Pump type Gas engine-driven, self-priming centrifugal
Current listed models FNSGF-5H and FNSGF-8H
Series maximum capacity Up to 165 GPM
Series maximum head Up to 185 ft
Maximum working pressure 120 PSI
Maximum liquid temperature 200 °F
Volute and impeller Cast iron; enclosed impeller
Mechanical seal Carbon/ceramic faces, FKM elastomers and stainless steel components
Pipe connections Threaded NPT / FNPT; size varies by model
Rotation Clockwise when viewed from the engine/shaft end
Mounting orientation Horizontal

The maximum flow, head and working pressure figures are separate published series limits; they do not represent a single simultaneous operating point. Use the performance information and your required flow, pressure and suction conditions to select a model.

Current FNSGF Pump Models and Ordering Information

These Honda-powered configurations appear in the manufacturer’s current ordering catalog. The item numbers link to their model-specific Kendisco pages.

Model Order Number Engine Displacement Suction NPT Discharge NPT Low-Oil Shutoff Weight
FNSGF-5H 90272105 Honda 160 cc 2 in. 2 in. Yes 94 lb
FNSGF-8H 90272108 Honda 270 cc 2-1/2 in. 2 in. Yes 118 lb

Additional Gasoline and Diesel Model References

The following models and item numbers were listed in older Kendisco ordering information. They are historical identification references, not a statement of current manufacturer availability. Verify the complete model code, engine, production date and availability before quoting or ordering. FNSDF designates the diesel variants.

Model Order Number Historical Engine Description Suction x Discharge (NPT) Listed Low-Oil Shutoff Listed Weight
FNSGF-5 90272005 Briggs & Stratton INTEK 2 x 2 in. No 94 lb
FNSGF-8 90272008 Briggs & Stratton INTEK 2-1/2 x 2 in. No 118 lb
FNSDF-5 90274005 Kohler diesel 2 x 2 in. No 134 lb
FNSDF-8-ES 90274108 Kohler diesel, electric-start variant 2-1/2 x 2 in. Yes 145 lb
FNSDF-8 90274008 Kohler diesel 2-1/2 x 2 in. No 145 lb

FNSGF Performance: Flow at Discharge Pressure

Franklin’s published performance table below reports U.S. gallons per minute at the stated discharge pressure with 5 feet of suction lift. Actual results vary with installation and system conditions.

Model 10 PSI 20 PSI 30 PSI 40 PSI 50 PSI 60 PSI 70 PSI 80 PSI
FNSGF-5H 132 115 106 85 70 52 Not listed Not listed
FNSGF-8H 165 162 145 125 110 85 50 30

Features and Applications

  • Self-priming cast iron volute: Tapped openings support initial filling, venting and draining. The built-in check valve helps the pump retain prime between operating cycles when the system is correctly installed and maintained.
  • Enclosed cast iron impeller and diffuser: Designed for higher-head water-transfer service. This pump is not a substitute for a solids-handling trash pump.
  • Engine-driven operation: Honda-powered current models use an air-cooled, four-stroke engine and adjustable throttle control for portable operation.
  • Replaceable service parts: Mechanical shaft seals, impellers, check-valve components, gaskets and other service items can be identified by model and figure number in the reference tables below.
  • Typical applications: Temporary irrigation, commercial water transfer, construction water supply, municipal support and light industrial water movement where liquid conditions and required head fall within the pump’s specifications.

FNSGF Replacement Parts and Exploded Diagram

Use the exploded view and parts references to identify the correct component for an existing pump. The matrix below includes older FNSGF model designations as well as the current Honda configurations; parts compatibility must be confirmed by full model and production information.

Franklin Electric FNSGF exploded pump parts diagram with component figure numbers

Fig. No. Part Description Part No. Materials of Construction
FNSGF-5 FNSGF-5H FNSGF-8 FNSGF-8H
1 FNSGF Pump Case 305460013 Cast Iron, ASTM-A48 CL30
2 FNSGF Impeller 305459004 305460014 Cast Iron, ASTM-A48 CL30
3 FNSGF Motor Adapter 305460015 305460016 Cast Iron, ASTM-A48 CL30
12 FNSGF  Sleeve 305458010 305459011 416 Stainless Steel
70 FNSGF Base, Engine Frame 305460017 305459016 CRS
72 FNSGF Check Valve 305455010 305460018 Cast Iron, ASTM-A48 CL30
73A FNSGF Top Weight – Check Valve 305455011 Cast Iron, ASTM-A48 CL30
73B FNSGF Bottom Weight – Check Valve 305455012 Cast Iron, ASTM-A48 CL30
74 FNSGF Diffuser 305460019 Cast Iron, ASTM-A48 CL30
77 FNSGF Handle 305460020 305459018 305459019 CRS
90 FNSGF Mechanical Shaft Seal 305463116 305463043 CARB/CER x FKM-SS
100A FNSGF Case Gasket 305463130 Neoprene
100B FNSGF Flapper Valve 305454043 Neoprene
100C FNSGF Square-Ring – Volute 305463131 Nitrile
200 FNSGF Engine See Below Misc.
500 FNSGF Pipe Plug 3/4″ (2 Req.) 305463050 CAD-Plated Steel
503 FNSGF Water Slinger 305458022 305456009 Neoprene
530A FNSGF Nut, Flapper 305463082 300 Series Stainless Steel
530B FNSGF Washer, Flapper 305463084 300 Series Stainless Steel
530C FNSGF Flapper Bolt 305463080 316 Stainless Steel
530D FNSGF Hex Bolts – Volute (4 Pack) 305463064 Zinc-Plated Steel
530E FNSGF Hex Bolt – Motor Adapter (4 Pack) 305463120 305463214 Zinc-Plated Steel
530F FNSGF Collar Seal – Motor Adapter (4 Pack) 305463107 N/A Nylon
Not Shown FNSGF Lockwasher – Motor Adapter (4 Pack) N/A 305463010 Zinc-Plated Steel
530G FNSGF Hex Bolt – Check Valve (12 Pack) 305463010 Zinc-Plated Steel
530H FNSGF Hex Bolt – Base (4 Pack) N/A 305463132 305463090 Zinc-Plated Steel
530J FNSGF Hex Nut – Base (4 Pack) 305463062 Zinc-Plated Steel
530K FNSGF Lockwasher – Base (4 Pack) 305463092 Zinc-Plated Steel
530L FNSGF Washer – Base (4 Pack) 305463109 Zinc-Plated Steel
530M FNSGF Bolt – Base Volute (4 Pack) 305463064 Zinc-Plated Steel
530N FNSGF Washer – Base Volute (4 Pack) 305463064 Zinc-Plated Steel
530P FNSGF Lockwasher – Base Volute (6 Pack) 305463137 Zinc-Plated Steel
532 FNSGF Spacer (4 Pack) 305463213 305463215 Cast Iron

Parts-reference update: Franklin’s current FNSGF catalog lists part 305463132 for the FNSGF-5H base hex bolt (figure 530H) and 305463137 for the base-volute lock washer (figure 530P). An older Kendisco record gave 305463032 for figure 530P. Confirm the correct part against the pump’s serial number and production revision before ordering.

Engine and Motor Reference Numbers

These engine-related part numbers are retained from the original Kendisco catalog, including historical gasoline and diesel references. Confirm availability and interchangeability for the specific engine model.

Model Motor Description Part No.
FNSGF-5 Eng B/S 120232-0136-B8 206CC 201915
FNSGF-5H Eng Honda GX160UT1TX2 5.5 hp OHV 202001
FNSGF-8 Eng B/S 201332-0158-B1 305CC 201918
FNSGF-8H Eng Honda GX270UTPA2 9 hp OHV 202002
FNSDF-5 Eng Kohler KD350-5001 6.7 hp 202061
FNSDF-8-ES Eng Kohler KD420-4001-9001 9.8 hp 202065
FNSDF-8 Eng Kohler KD420-3100 9.8 hp 202064

Replacement Pump End Kits (Without Engine)

Franklin’s engine-driven pump catalog also lists the following pump-end kits, supplied without an engine. Match the kit’s shaft size and installation requirements before ordering.

Kit Order Number Shaft Type Shaft Size Kit Weight
FNSGF-5PEK 90275005 Threaded 5/8 in. 62 lb
FNSGF-8PEK 90275008 Threaded 1 in. 76 lb

FNSGF Dimensions

Dimensions are provided for estimating purposes. All dimensions are in inches and correspond to the dimensional drawing.

Franklin Electric FNSGF-5H and FNSGF-8H pump dimensional drawing

Model Discharge (in.) Suction (in.) A B C D E
FNSGF-5H 2 2 9.75 13.50 16.20 20.25 14.38
FNSGF-8H 2 2-1/2 13.00 17.00 17.31 23.66 17.75

FNSGF Performance Curve

Franklin Electric FNSGF gasoline engine self-priming pump performance curve

Installation and Pump Selection Notes

  • Initial filling: Fill the casing with water before starting. Never run the pump dry. Successful repeat priming depends on a working built-in check valve and an airtight suction system.
  • Pipe and hose sizes: Use model-specific NPT connection dimensions. FNSGF-8H has a larger 2-1/2-inch suction connection and a 2-inch discharge connection.
  • Engine setup: Follow the supplied Honda engine owner’s manual and pump manual for engine oil, fuel, safe ventilation and operating procedures.
  • Water quality: The enclosed impeller is intended for water-transfer service. If the water contains substantial sediment or debris, review a more appropriate solids-handling pump such as the FMIG series.
  • Model selection: Choose by required flow at operating head, suction lift, port size, engine configuration and compatibility with the intended liquid.

Frequently Asked Questions About Franklin Electric FNSGF Pumps

What is the difference between FNSGF-5H and FNSGF-8H?

The FNSGF-5H uses a 160 cc Honda engine with 2-inch suction and discharge ports. The FNSGF-8H uses a 270 cc Honda engine with a 2-1/2-inch suction and 2-inch discharge. Their flow ratings also differ across the published pressure curve; compare performance at your actual system head before selecting a model.

Does the FNSGF pump need to be primed?

Yes. Fill the pump casing before initial startup. The self-priming design and built-in check valve can support subsequent starts when the system retains liquid and the suction plumbing is airtight. Check the manufacturer’s manual before operation.

Is the FNSGF suitable for water containing sand or debris?

The enclosed impeller is intended primarily for relatively clean water and higher-pressure transfer duties. For water with significant suspended solids, ask Ken’s Distributing Company about a suitable semi-open-impeller or solids-handling alternative.

Are Briggs & Stratton or Kohler diesel models available?

Older Kendisco catalogs list Briggs & Stratton gasoline FNSGF models and Kohler diesel FNSDF variants. Franklin’s current FNSGF ordering page lists the Honda-powered FNSGF-5H and FNSGF-8H. Contact Ken’s Distributing Company for the status of historical engine configurations or replacement parts.

Can I order FNSGF pump-end kits or repair parts separately?

Franklin’s catalog includes FNSGF-5PEK and FNSGF-8PEK pump-end kit references. Pump cases, impellers, seals, diffuser and check-valve components are identified in the parts table. Supply the model and engine or pump serial number when requesting a replacement component.

Related Franklin Electric Pumps and Replacement Parts

Request a Quote for an FNSGF Pump or Replacement Part

Contact Ken’s Distributing Company to discuss an FNSGF-5H or FNSGF-8H pump, an older FNSGF or FNSDF unit, or a replacement component. Share your model or item number and the flow, head and application requirements so the team can help identify the appropriate product. Call 303-699-7845 or use the quote form on this product page.

Send us your model number and we will confirm fit, price, and availability.

Products Form