Monarch Industries ACE Water Pumps
- ACE-50 to ACE-200 C-face pumps from 1/2 to 2 HP
- ACE-S square flange models with glass-filled Noryl impellers
- ACE-300 and ACE-500 JM frame pumps in 3 and 5 HP
- C-face and JM models have seals rated for 200 degree F water
- ACE-50 to ACE-200 cross to Franklin FAC 50S to FAC 200T
- Tell us your ACE model and we will confirm the parts
Your pump is dripping at the seal, or the motor hums and trips, and the nameplate still reads ACE. The Monarch ACE pump C-face models have been replaced by the Franklin Electric FAC, and ACE seals, impellers, gaskets, and motors can still be matched by code number. This page covers all three ACE builds, their order numbers, the parts that wear, and where the FAC fits.
Which ACE Models Have a Franklin FAC Match?
The ACE-33 through ACE-200 C-face pumps were replaced by the Franklin Electric FAC 50S through FAC 200T, and parts interchange between the two. The ACE-S square flange and the ACE-300 and ACE-500 JM frame pumps have no confirmed one-for-one match yet. Send us the model number and we will confirm the current equivalent.
Three ACE Builds by Motor Mount
- ACE (C-face): 1/2 to 2 HP on a 56J C-face motor at 3600 RPM, with a cast gray iron casing and impeller.
- ACE-S (square flange): 1/2 to 2 HP on a square flange motor with thermal overload protection, and an enclosed glass-filled Noryl impeller with a stainless steel hub.
- ACE-300 and ACE-500 (JM frame): 3 and 5 HP on a JM motor at 3600 RPM, in single phase or three phase.
Monarch ACE Model Table
Port sizes are NPT, suction by discharge. Less Power kits are the pump end only, for mounting on a motor you already own.
| Model | Order No. | HP | Ports | Power | Less Power kit |
|---|---|---|---|---|---|
| ACE-50 | 615030 | 1/2 | 1-1/4" x 1" | Single phase | ACE-50LP, 615037 |
| ACE-75 | 615040 | 3/4 | 1-1/2" x 1-1/4" | Single phase | ACE-75LP, 615047 |
| ACE-100 | 615050 | 1 | 1-1/2" x 1-1/4" | Single phase | ACE-100LP, 615057 |
| ACE-150 | 615060 | 1-1/2 | 2" x 1-1/2" | Single phase | ACE-150LP, 615068 |
| ACE-200 | 615070 | 2 | 2" x 1-1/2" | Single phase | ACE-200LP, 615076 |
| ACE-S50SD | 614561 | 1/2 | 1-1/4" x 1" | 115/230V, 1 phase | None listed |
| ACE-S75SD | 614562 | 3/4 | 1-1/4" x 1" | 115/230V, 1 phase | None listed |
| ACE-S100SD | 614563 | 1 | 1-1/4" x 1" | 115/230V, 1 phase | None listed |
| ACE-S150SD | 614564 | 1-1/2 | 1-1/4" x 1" | 115/230V, 1 phase | None listed |
| ACE-S200SD | 614565 | 2 | 1-1/2" x 1-1/4" | Single phase | None listed |
| ACE-300SD | 614571 | 3 | 2" x 2" | 230V, 1 phase | ACE-300LP, 614995 |
| ACE-300-3SD | 614567 | 3 | 2" x 2" | 208-230/460V, 3 phase | ACE-300LP, 614995 |
| ACE-500SD | 614569 | 5 | 2" x 2" | 230V, 1 phase | ACE-500LP, 614996 |
| ACE-500-3SD | 614570 | 5 | 2" x 2" | 208-230/460V, 3 phase | ACE-500LP, 614996 |
Need more flow than 5 HP gives you? The larger Monarch EPE end suction pumps run up to 30 HP in sizes up to 4 x 3 inches.
Monarch ACE Pump Repair Parts That Wear
Each ACE build has its own parts list. These are the codes buyers ask about first.
- Mechanical seal: 240250, a 5/8 inch Type 6 seal, fits the C-face ACE and the ACE-S. The ACE-300 and ACE-500 use seal MS-7, code 240070.
- Gaskets: 193900 fits the ACE-33 to ACE-100, and 193910 fits the ACE-150 and ACE-200. On the ACE-S, 193914 fits 1/2 to 1 HP and 193915 fits 1-1/2 and 2 HP.
- Impellers: each horsepower has its own impeller, such as 437790 for the ACE-150 and 437800 for the ACE-200. Moving up in HP means a new impeller and a new motor.
- Flinger: 191790 is shared by the C-face ACE and the ACE-S.
- Spares to stock: the parts list for the C-face ACE suggests keeping the aluminum washer, gasket, and seal on hand.
Hot Water Seals and Winter Drain Ports
The C-face and JM frame ACE pumps carry high temperature mechanical seals rated for water up to 200 degrees F. That makes them a fit for hot water circulation as well as cold water transfer.
Every ACE has ports for bleeding air during priming and for draining the casing before a freeze. A shaft flinger and a large drain hole in the adapter keep water away from the motor bearings.
Buying a New FAC in Place of an ACE
For an ACE-50 to ACE-200, the Franklin FAC 50S to FAC 200T is the cross-reference. Browse current models among the Franklin Electric close-coupled centrifugal pumps.
For an ACE-S or a JM frame ACE-300 or ACE-500, send the model number first. We will confirm the current equivalent before you order.
Water Below the Pump or Solids in It? Skip the ACE
- The water sits below the pump. The ACE is not self-priming, so it needs a flooded suction or a primed casing and a foot valve. A self-priming BSE utility pump lifts water on its own.
- The water carries sewage or solids. The ACE is built for clear water and light transfer, not for passing solids.
- You want a different series. Compare jet, sprinkler, and self-priming series on the Monarch electric motor pump hub.
Frequently Asked Questions
What is the difference between the ACE and ACE-S?
The difference between the ACE and the ACE-S is the motor mount and the impeller. The ACE-50 to ACE-200 bolt to a 56J C-face motor and use a cast gray iron impeller. The ACE-S models bolt to a square flange motor and use an enclosed glass-filled Noryl impeller with a stainless steel hub. Casings, gaskets, and impellers are not shared between the two, so check the model name before you order parts.
Are the ports on the ACE-150 and ACE-200 larger than other ACE models?
Yes, the ports on the ACE-150 and ACE-200 are larger than on the smaller C-face ACE models. Both have a 2 inch NPT suction and a 1-1/2 inch NPT discharge. The ACE-50 uses a 1-1/4 inch suction and 1 inch discharge, and the ACE-75 and ACE-100 use a 1-1/2 inch suction and 1-1/4 inch discharge. The larger pair also takes its own gasket, code 193910, in place of the 193900 used on the smaller models.
Can I upgrade an ACE-150 to an ACE-200 by changing the motor?
No, you cannot upgrade an ACE-150 to an ACE-200 by changing the motor alone. The two share the same casing (437732), electric adapter (437900), and gasket (193910). The impeller is different, code 437790 on the ACE-150 and 437800 on the ACE-200, and the motor moves from 1-1/2 HP (204180) to 2 HP (204190). Swap both the impeller and the motor, and check that your wiring suits the 2 HP motor.
Ready to order? Send us your ACE model number and we will quote the seal, impeller, motor, or FAC replacement that fits.