Franklin Electric BT4 Series Booster Pump models provide multi-stage water-pressure boosting for residential, agricultural and commercial systems. Choose from 5 to 25 GPM models with 1-inch NPT ports, 35 to 45 GPM models with 1.5-inch NPT ports, or motorless NEMA 56C pump ends. Ken’s Distributing Company supplies BT4 pumps and helps identify the correct OEM replacement parts by model and item number.

Need a complete pump or repair parts? Send us the BT4 model or item number, available voltage, required flow and target outlet pressure. We can confirm configuration, fit, price and availability for buyers across the United States and Canada. We reply within one business day.

The MH Series is listed with it under Franklin horizontal booster pumps, so you can compare flow and pressure ranges.

Franklin Electric BT4 Series Booster Pump: Key Specifications

Selection factor Manufacturer specifications / selection guidance
Nominal flow families 5, 7, 10, 15, 20 and 25 GPM; 35 and 45 GPM
Motor options Single-phase or three-phase complete pumps; separate NEMA 56C pump ends without a motor
Horsepower in linked complete-pump tables 1/2 to 3 HP, depending on the specific model
Suction and discharge, 5–25 GPM 1-inch female NPT
Suction and discharge, 35–45 GPM 1.5-inch female NPT
Maximum inlet pressure 75 PSI
Maximum discharge pressure, product specification 400 PSI; this is a system limit, not the pressure delivered at every flow
Maximum operating pressure, 2025 owner’s manual 500 PSI is separately specified in the manual; confirm the complete system’s applicable lower-rated component
Maximum liquid temperature 120°F (49°C)
Material, 5–25 GPM hydraulics Acetal impellers, modified PPO diffusers, stainless steel hydraulic components
Motor type, 5–25 GPM ODP square-flange, dual-voltage or three-phase models as listed
Motor type, 35–45 GPM NEMA 56C, with enclosure and phase depending on suffix/model
Potable water-related certification NSF/ANSI/CAN 372 lead-content compliance for designated BT4 products; confirm project-specific potable-water approvals
Automatic control External control/pressure-switch selection required; not all pump assemblies include an automatic controller

Performance note: The flow numbers identify nominal model families, not guaranteed delivery at a specified pressure. Determine the duty point using the chosen model’s performance curve, available inlet pressure and plumbing losses. The owner’s manual separately states a 500 PSI maximum operating-pressure rating, while Franklin’s product overview gives 400 PSI as its maximum discharge-pressure specification; neither should be used as a promised output pressure.

Choose the BT4 Configuration That Fits Your System

BT4 product group Nominal flow Connections Motor supplied? Best use / important distinction
5–25 GPM integrated motor pump 5–25 GPM 1 in. NPT Yes Residential well and municipal-supply boosting; Tri-Seal floating stages
35–45 GPM integrated motor pump 35 or 45 GPM 1.5 in. NPT Yes Higher-flow commercial pressure boosting; larger NEMA 56C arrangement
56C pump end only 5–45 GPM 1 or 1.5 in. NPT by flow group No Use a separately selected, compatible NEMA 56C keyed-shaft motor

For new installations, first specify required GPM and total dynamic head or target discharge pressure. Next select horsepower, voltage and phase, followed by the motor-enclosure or pump-end arrangement. The same nominal flow is sold in several stage counts and motor ratings, so the item number matters.

BT4 Complete Pumps by Model and Manufacturer Item Number

The manufacturer item numbers below are the ordering references. Each underlined item number links once to its existing dedicated Ken’s Distributing product page. Flow is the nominal catalog series designation, not guaranteed flow at every head.

5–25 GPM Single-Phase BT4 Pumps

Item Model HP Phases Volts Flow
95830710 7FBT05S4 1/2 hp Single-Phase 115 VAC / 230 VAC 7 gpm
95831010 10FBT05S4 1/2 hp Single-Phase 115 VAC / 230 VAC 10 gpm
95830515 5FBT07S4 3/4 hp Single-Phase 115 VAC / 230 VAC 5 gpm
95830715 7FBT07S4 3/4 hp Single-Phase 115 VAC / 230 VAC 7 gpm
95831015 10FBT07S4 3/4 hp Single-Phase 115 VAC / 230 VAC 10 gpm
95831515 15FBT07S4 3/4 hp Single-Phase 115 VAC / 230 VAC 15 gpm
95832015 20FBT07S4 3/4 hp Single-Phase 115 VAC / 230 VAC 20 gpm
95830520 5FBT1S4 1 hp Single-Phase 115 VAC / 230 VAC 5 gpm
95830720 7FBT1S4 1 hp Single-Phase 115 VAC / 230 VAC 7 gpm
95831020 10FBT1S4 1 hp Single-Phase 115 VAC / 230 VAC 10 gpm
95831520 15FBT1S4 1 hp Single-Phase 115 VAC / 230 VAC 15 gpm
95832020 20FBT1S4 1 hp Single-Phase 115 VAC / 230 VAC 20 gpm
95832520 25FBT1S4 1 hp Single-Phase 115 VAC / 230 VAC 25 gpm
95830725 7FBT15S4 1.5 hp Single-Phase 115 VAC / 230 VAC 7 gpm
95831025 10FBT15S4 1.5 hp Single-Phase 115 VAC / 230 VAC 10 gpm
95831525 15FBT15S4 1.5 hp Single-Phase 115 VAC / 230 VAC 15 gpm
95832025 20FBT15S4 1.5 hp Single-Phase 115 VAC / 230 VAC 20 gpm
95832525 25FBT15S4 1.5 hp Single-Phase 115 VAC / 230 VAC 25 gpm
95831030 10FBT2S4 2 hp Single-Phase 115 VAC / 230 VAC 10 gpm
95831530 15FBT2S4 2 hp Single-Phase 115 VAC / 230 VAC 15 gpm
95832030 20FBT2S4 2 hp Single-Phase 115 VAC / 230 VAC 20 gpm
95832530 25FBT2S4 2 hp Single-Phase 115 VAC / 230 VAC 25 gpm
95832035 20FBT3S4 3 hp Single-Phase 230 VAC 20 gpm
95832535 25FBT3S4 3 hp Single-Phase 230 VAC 25 gpm
95830510 5FBT05S4 1/2 hp Single-Phase 115 VAC / 230 VAC 5 gpm

5–25 GPM Three-Phase BT4 Pumps

Item Model HP Phases Volts Flow
95830555 5FBT05S4-T 1/2 hp Three-Phase 230 VAC / 460 VAC 5 gpm
95830755 7FBT05S4-T 1/2 hp Three-Phase 230 VAC / 460 VAC 7 gpm
95831055 10FBT05S4-T 1/2 hp Three-Phase 230 VAC / 460 VAC 10 gpm
95830560 5FBT07S4-T 3/4 hp Three-Phase 230 VAC / 460 VAC 5 gpm
95830760 7FBT07S4-T 3/4 hp Three-Phase 230 VAC / 460 VAC 7 gpm
95831060 10FBT07S4-T 3/4 hp Three-Phase 230 VAC / 460 VAC 10 gpm
95831560 15FBT07S4-T 3/4 hp Three-Phase 230 VAC / 460 VAC 15 gpm
95832060 20FBT07S4-T 3/4 hp Three-Phase 230 VAC / 460 VAC 20 gpm
95830565 5FBT1S4-T 1 hp Three-Phase 230 VAC / 460 VAC 5 gpm
95830765 7FBT1S4-T 1 hp Three-Phase 230 VAC / 460 VAC 7 gpm
95831065 10FBT1S4-T 1 hp Three-Phase 230 VAC / 460 VAC 10 gpm
95831565 15FBT1S4-T 1 hp Three-Phase 230 VAC / 460 VAC 15 gpm
95832065 20FBT1S4-T 1 hp Three-Phase 230 VAC / 460 VAC 20 gpm
95832565 25FBT1S4-T 1 hp Three-Phase 230 VAC / 460 VAC 25 gpm
95830770 7FBT15S4-T 1.5 hp Three-Phase 230 VAC / 460 VAC 7 gpm
95831070 10FBT15S4-T 1.5 hp Three-Phase 230 VAC / 460 VAC 10 gpm
95831570 15FBT15S4-T 1.5 hp Three-Phase 230 VAC / 460 VAC 15 gpm
95832070 20FBT15S4-T 1.5 hp Three-Phase 230 VAC / 460 VAC 20 gpm
95832570 25FBT15S4-T 1.5 hp Three-Phase 230 VAC / 460 VAC 25 gpm
95831075 10FBT2S4-T 2 hp Three-Phase 230 VAC / 460 VAC 10 gpm
95831575 15FBT2S4-T 2 hp Three-Phase 230 VAC / 460 VAC 15 gpm
95832075 20FBT2S4-T 2 hp Three-Phase 230 VAC / 460 VAC 20 gpm
95832575 25FBT2S4-T 2 hp Three-Phase 230 VAC / 460 VAC 25 gpm
95832080 20FBT3S4-T 3 hp Three-Phase 230 VAC / 460 VAC 20 gpm
95832580 25FBT3S4-T 3 hp Three-Phase 230 VAC / 460 VAC 25 gpm

35–45 GPM Single-Phase BT4 Pumps

Item Model HP Phases Volts Flow
95933503 3503FBT1S4-S 1 hp Single-Phase 115 VAC / 230 VAC 35 gpm
95983503 3503FBT1S4-SE 1 hp Single-Phase 115 VAC / 230 VAC 35 gpm
95934502 4502FBT1S4-S 1 hp Single-Phase 115 VAC / 230 VAC 45 gpm
95934503 4503FBT1S4-S 1 hp Single-Phase 115 VAC / 230 VAC 45 gpm
95984502 4502FBT1S4-SE 1 hp Single-Phase 115 VAC / 230 VAC 45 gpm
95933505 3505FBT15S4-S 1.5 hp Single-Phase 115 VAC / 230 VAC 35 gpm
95983505 3505FBT15S4-SE 1.5 hp Single-Phase 115 VAC / 230 VAC 35 gpm
95934504 4504FBT15S4-S 1.5 hp Single-Phase 115 VAC / 230 VAC 45 gpm
95984504 4504FBT15S4-SE 1.5 hp Single-Phase 115 VAC / 230 VAC 45 gpm
95933507 3507FBT2S4-S 2 hp Single-Phase 115 VAC / 230 VAC 35 gpm
95934505 4505FBT2S4-S 2 hp Single-Phase 115 VAC / 230 VAC 45 gpm
95934506 4506FBT2S4-S 2 hp Single-Phase 115 VAC / 230 VAC 45 gpm
95984505 4505FBT2S4-SE 2 hp Single-Phase 115 VAC / 230 VAC 45 gpm
95984506 4506FBT2S4-SE 2 hp Single-Phase 115 VAC / 230 VAC 45 gpm
95983507 3507FBT2S4-SE 2 hp Single-Phase 230 VAC 35 gpm
95933509 3509FBT3S4-S 3 hp Single-Phase 230 VAC 35 gpm
95983509 3509FBT3S4-SE 3 hp Single-Phase 230 VAC 35 gpm
95934507 4507FBT3S4-S 3 hp Single-Phase 230 VAC 45 gpm
95984507 4507FBT3S4-SE 3 hp Single-Phase 230 VAC 45 gpm

35–45 GPM Three-Phase BT4 Pumps

Item Model HP Phases Volts Flow
95583503 3503FBT1S4-TE 1 hp Three-Phase 208-230 VAC / 460 VAC 35 gpm
95993503 3503FBT1S4-T 1 hp Three-Phase 208-230 VAC / 460 VAC 35 gpm
95584502 4502FBT1S4-TE 1 hp Three-Phase 208-230 VAC / 460 VAC 45 gpm
95994502 4502FBT1S4-T 1 hp Three-Phase 208-230 VAC / 460 VAC 45 gpm
95994503 4503FBT1S4-T 1 hp Three-Phase 208-230 VAC / 460 VAC 45 gpm
95583505 3505FBT15S4-TE 1.5 hp Three-Phase 208-230 VAC / 460 VAC 35 gpm
95993505 3505FBT15S4-T 1.5 hp Three-Phase 208-230 VAC / 460 VAC 35 gpm
95584504 4504FBT15S4-TE 1.5 hp Three-Phase 208-230 VAC / 460 VAC 45 gpm
95994504 4504FBT15S4-T 1.5 hp Three-Phase 208-230 VAC / 460 VAC 45 gpm
95583507 3507FBT2S4-TE 2 hp Three-Phase 208-230 VAC / 460 VAC 35 gpm
95993507 3507FBT2S4-T 2 hp Three-Phase 208-230 VAC / 460 VAC 35 gpm
95584505 4505FBT2S4-TE 2 hp Three-Phase 208-230 VAC / 460 VAC 45 gpm
95584506 4506FBT2S4-TE 2 hp Three-Phase 208-230 VAC / 460 VAC 45 gpm
95994505 4505FBT2S4-T 2 hp Three-Phase 208-230 VAC / 460 VAC 45 gpm
95583509 3509FBT3S4-TE 3 hp Three-Phase 208-230 VAC / 460 VAC 35 gpm
95993509 3509FBT3S4-T 3 hp Three-Phase 208-230 VAC / 460 VAC 35 gpm
95584507 4507FBT3S4-TE 3 hp Three-Phase 208-230 VAC / 460 VAC 45 gpm
95994507 4507FBT3S4-T 3 hp Three-Phase 208-230 VAC / 460 VAC 45 gpm

BT4 56C Pump Ends Without Motors

Order a 56C pump end when the installation calls for a separately selected NEMA 56C keyed-shaft motor. These are not complete motor-driven booster packages. The list includes manufacturer options for 5-, 20-, 35- and 45-GPM pump ends. Confirm motor speed, enclosure, horsepower, shaft dimensions and coupling fit before ordering.

56C Pump-End Ordering Numbers

Item Model Flow HP
95920509 5BT05S4-PE 5 gpm 1/2 hp
95920512 5BT07S4-PE 5 gpm 3/4 hp
95920515 5BT1S4-PE 5 gpm 1 hp
95920708 7BT05S4-PE 7 gpm 1/2 hp
95920710 7BT07S4-PE 7 gpm 3/4 hp
95920714 7BT1S4-PE 7 gpm 1 hp
95920719 7BT15S4-PE 7 gpm 1.5 hp
95921007 10BT05S4-PE 10 gpm 1/2 hp
95921008 10BT07S4-PE 10 gpm 3/4 hp
95921011 10BT1S4-PE 10 gpm 1 hp
95921015 10BT15S4-PE 10 gpm 1.5 hp
95921018 10BT2S4-PE 10 gpm 2 hp
95921506 15BT07S4-PE 15 gpm 3/4 hp
95921508 15BT1S4-PE 15 gpm 1 hp
95921512 15BT15S4-PE 15 gpm 1.5 hp
95921515 15BT2S4-PE 15 gpm 2 hp
95922513 25BT3S4-PE 25 gpm 3 hp
95922506 25BT1S4-PE 25 gpm 1 hp
95922508 25BT15S4-PE 25 gpm 1.5 hp
95922510 25BT2S4-PE 25 gpm 2 hp

Additional 56C Pump-End Options Listed by Franklin Electric

Item number Pump-end model Nominal flow Motor HP required
95920507 5BT03S4-PE 5 GPM 1/3 HP
95922005 20BT07S4-PE 20 GPM 3/4 HP
95922007 20BT1S4-PE 20 GPM 1 HP
95922010 20BT15S4-PE 20 GPM 1.5 HP
95922012 20BT2S4-PE 20 GPM 2 HP
95922015 20BT3S4-PE 20 GPM 3 HP
95923503 3503FBT1S4-PE 35 GPM 1 HP
95923505 3505FBT15S4-PE 35 GPM 1.5 HP
95923507 3507FBT2S4-PE 35 GPM 2 HP
95923509 3509FBT3S4-PE 35 GPM 3 HP
95924502 4502FBT1S4-PE 45 GPM 1 HP (2 stages)
95924503 4503FTB1S4-PE 45 GPM 1 HP (3 stages)
95924504 4504FBT15S4-PE 45 GPM 1.5 HP
95924505 4505FBT2S4-PE 45 GPM 2 HP (5 stages)
95924506 4506FBT2S4-PE 45 GPM 2 HP (6 stages)
95924507 4507FBT3S4-PE 45 GPM 3 HP

Franklin’s published catalog spells model 4503FTB1S4-PE for item 95924503. Confirm the nameplate/model spelling when requesting this pump end.

How BT4 Multi-Stage Pressure Boosting Works

Inside a BT4, water flows through a series of impeller-and-diffuser stages. Each stage adds head, allowing a relatively compact unit to deliver high pressure while serving the model’s rated flow family. The patented Tri-Seal floating-stage design appears in Franklin’s 5–25 GPM range, with acetal impellers, modified PPO diffusers and 300-series stainless-steel wetted metal components.

For the larger 35- and 45-GPM models, Franklin uses hydraulic stages designed for their higher nominal flows, 1.5-inch connections, a rotatable bracket and NEMA 56C motor mounting. The two ranges should be sized using their own curves rather than treating all BT4 units as interchangeable.

BT4 Applications and Automatic Pressure Controls

  • Home and light-commercial boosting: Raise water pressure where municipal or private supply pressure is inadequate, with a properly selected pressure switch, tank or controller.
  • Commercial water distribution: Select higher-flow 35- and 45-GPM models when the duty point calls for more water than smaller BT4 hydraulics can provide.
  • Filtration and reverse-osmosis feed: Match inlet and discharge conditions to equipment pressure limits and water-treatment specifications.
  • Irrigation, spray and misting systems: Use the manufacturer curve to select the necessary flow at operating pressure.
  • Equipment replacement: Identify the existing BT4 motor rating, item number and stage count before choosing a complete pump or pump end.

Is the BT4 automatic? A standard BT4 assembly is a pump, not a complete automatic pressure-control system. Automatic start/stop operation needs suitable external controls. See the related Franklin Electric Inline Controls product below, and confirm voltage, current, motor type and application compatibility before ordering controls.

OEM BT4 Replacement Parts: Seals, O-Rings, Bearings and Couplings

Many BT4 repairs do not require a complete new pump. Franklin Electric publishes OEM part numbers for mechanical seals, shaft coupling kits, O-rings, stage assemblies, top bearings and discharge heads. To request repair parts, identify the 5–25 GPM or 35/45 GPM version, complete pump or 56C pump-end style, and original item/model number.

OEM part number Replacement component Catalog applicability
305421902 Coupling kit with mechanical seal, stainless steel 5–25 GPM pump assemblies
305421001 Coupling kit with mechanical seal and two set screws 56C pump-end mounting; all flow groups
305421002 Stainless-steel pump/motor bracket 5–25 GPM, 56C pump-end mounting
305421972 Pump/motor bracket 35 or 45 GPM
305421906 Mechanical seal, FKM/Viton option 5–25 GPM
305421907 Mechanical seal, Buna option 5–25 GPM
305421003 Mechanical seal, FKM/Viton 56C pump-end mounting
305421908 O-ring set All flow groups; verify variant
305421909 Top bearing 5–25 GPM
305421973 Top bearing 35 GPM
305421974 Top bearing 45 GPM
305421910 Discharge head 5–25 GPM
305421975 Discharge head 35 or 45 GPM
305421934 Suction seal spacer All flow groups
305421935 Discharge seal spacer All flow groups
305404928 Diffuser/impeller/disk stage assembly 35 GPM
305404929 Diffuser/impeller/disk stage assembly 45 GPM

BT4 Stage Assembly Part Numbers by Flow Family

The stage-assembly number can differ by flow family, motor horsepower and stage count. Franklin’s service manual lists these OEM stage assembly references. Confirm the full BT4 model and stage count before ordering.
Match the stage assembly to your motor HP before ordering.

OEM stage assembly Nominal flow Compatibility note
305404911 5 GPM Selected 5-GPM configurations
305404912 7 GPM Selected 7-GPM configurations
305404913 10 GPM Selected 10-GPM configurations
305404914 15 GPM Selected 15-GPM configurations
305404915 20 GPM Selected 20-GPM configurations
305404916 25 GPM Selected 25-GPM configurations
305404928 35 GPM Higher-flow BT4 hydraulic
305404929 45 GPM Higher-flow BT4 hydraulic

For parts service, ask for the OEM item number and required quantity (for example, a single stage assembly versus a complete set of stages). O-rings, seals, spacers and bearings must match the pump-end design and service revision.

Repair the BT4 Booster Pump or Replace the Complete Unit?

  • Replace a seal or O-ring: Consider OEM parts when the motor, stages and pump body remain serviceable and leakage comes from an identified sealing component.
  • Repair or replace stage components: Damaged impellers or diffusers can change flow and head. Confirm the original stage count and parts needed for the exact BT4 variant.
  • Replace a motor or pump end: For failed motors, compare motor replacement with a 56C pump-end configuration where appropriate. Confirm the shaft and motor mounting before quoting.
  • Request a complete BT4 assembly: If multiple hydraulic parts are damaged or a new duty point is required, an appropriately selected new complete pump may be more practical.

BT4 vs. MH Series: Which Booster Pump Fits?

Selection point BT4 Series MH Series
Flow families on this page 5–45 GPM Other residential and commercial flow families, including higher-flow models
Primary advantage Multi-stage high-pressure booster selection, including motorless 56C pump ends Alternative pressure-boosting and circulation configurations
Maximum liquid temperature 120°F Model dependent; verify the specific MH unit
Connection and voltage 1 or 1.5 in. NPT; model-dependent motor Model-dependent
How to decide Select by GPM at duty head and installation power Compare application-specific performance curves

Do not select solely on maximum pressure. Compare GPM at the required head, motor and electrical supply, allowable fluid temperature, pressure control requirements and the available piping layout.

Installation and Model Compatibility Checklist

  • Confirm the pump supply and all downstream components are rated for the expected inlet pressure plus pump-generated pressure.
  • Use correctly sized suction and discharge plumbing with adequate inlet water and follow the manufacturer’s priming instructions.
  • Select the proper electrical supply and check overload protection and motor enclosure for the installation.
  • Choose the compatible control method: pressure switch and tank, or a manufacturer-approved inline control arrangement.
  • For a 56C pump end, specify the actual motor and keyed shaft rather than assuming the pump end includes a motor.
  • For repairs, note whether the unit is 5–25 GPM or 35–45 GPM and provide its complete OEM model/item number.

Request BT4 Pump Prices, Availability or OEM Repair Parts

For complete pumps: Send the required flow (GPM), desired pressure or total dynamic head, incoming pressure, available voltage, single- or three-phase supply, and whether you need a motorized unit or pump end. A photo of the original nameplate is useful for direct replacements.

For OEM replacement parts: Send the pump model, item number and suspected part or part number, plus the condition being repaired. Ken’s Distributing Company can help confirm fit, price and availability. Request a BT4 pump or parts quote, or call 303-699-7845.

Frequently Asked Questions

Is the Franklin Electric BT4 booster pump automatic?

The BT4 itself is a multi-stage pump. An automatic pressure-boosting installation needs compatible external controls such as a pressure switch or suitable inline pump controller. Confirm controller and motor electrical compatibility before ordering.

Which BT4 pump fits a 10-GPM pressure-boosting application?

Several 10-GPM BT4 models have different horsepower and stage counts. Select by required pressure or total dynamic head at the design flow, then match voltage and motor phase. Compare the model/item-number tables above.

What is the difference between a 56C pump end and a complete BT4 pump?

A 56C pump end contains the hydraulic pump assembly for use with a separately supplied NEMA 56C keyed-shaft motor. A complete BT4 assembly includes the motor indicated by its specific ordering row.

Does the BT4 produce 400 PSI at 45 GPM?

Not necessarily. Franklin’s 400 PSI figure is a maximum discharge-pressure specification, not a simultaneous flow-and-pressure operating point. Select the exact motor and stage configuration from its performance curve.

Which BT4 mechanical seal and O-ring parts can I request?

Manufacturer-listed examples include mechanical seals 305421906 and 305421907, 56C pump-end seal 305421003 and O-ring set 305421908. The correct component depends on the pump version and repair scope.

Does NSF/ANSI/CAN 372 mean the entire pump is approved for every drinking-water installation?

No. NSF/ANSI/CAN 372 addresses lead-content requirements for designated water-contact products. Confirm all additional local plumbing, water-quality and system requirements for the specific installation.

Can I buy an individual BT4 impeller or diffuser stage rather than the whole pump?

Yes, Franklin lists replacement diffuser/impeller/disk stage assemblies by nominal flow, plus other service components. Provide the full BT4 model and stage count to confirm the correct OEM part.

Can I run a BT4 with a variable-frequency drive?

Franklin describes the three-phase 5–25 GPM motor models as inverter-duty rated. Select and program the drive to match the actual motor nameplate and manufacturer guidance. Do not assume the same arrangement applies to single-phase motors.