Franklin Electric FACGF Gas Engine Centrifugal Pumps
FACGF Pump Manuals & Resources
The Franklin Electric FACGF gas engine driven centrifugal pump series is designed for water transfer, irrigation, construction, mining, commercial, municipal, and light industrial applications where a gasoline engine provides power without an onsite electrical connection. The series combines a cast iron volute, enclosed cast iron impeller, and mechanical shaft seal in a horizontally mounted pump-and-engine assembly.
Models include the FACGF-5, FACGF-5H, FACGF-8H, and FACGF-23K. Engine configurations span Briggs & Stratton, Honda, and Kohler, with suction and discharge ports from 2 inches to 2.5 inches depending on the model. Ken’s Distributing Company can help identify the appropriate model, verify current availability, and locate replacement parts.
Franklin Electric FACGF Features and Specifications
- Pump design: Gas engine driven, end-suction centrifugal pump. Not self-priming.
- Volute: Rugged cast iron construction with vent and drain openings.
- Impeller: Enclosed cast iron for pressure-oriented water pumping applications.
- Mechanical seal: Carbon/ceramic faces, FKM (fluoroelastomer) elastomers, and stainless steel components.
- Installation: Horizontal mounting; NPT threaded suction and discharge connections.
- Engine: Model-dependent Briggs & Stratton, Honda, or Kohler gasoline engine; adjustable throttle.
- Series maximum capacity: Up to 270 US GPM.
- Series maximum head: Up to 240 feet.
- Maximum working pressure: 150 PSI; maximum liquid temperature: 200°F.
- Rotation: Clockwise when viewed from motor/engine end, per the series catalog.
Maximum flow, maximum head, and maximum allowable working pressure are separate specifications. Actual flow at a given discharge head depends on the model and operating conditions. Use the published performance curve and verify suitability before ordering.
FACGF Models and Current Manufacturer Listings
Compare the four configurations currently shown by Franklin Electric. Select an item number to view the corresponding Kendisco model page.
| Item | Model | Engine Brand For Driven Pumps | Engine Size – Driven Pumps (CC) | Suction Diameter | Discharge Diameter |
|---|---|---|---|---|---|
| 90261005 | FACGF-5 | Briggs & Stratton | 205 | 2 “ | 2 “ |
| 90261105 | FACGF-5H | Honda | 160 | 2 “ | 2 “ |
| 90261108 | FACGF-8H | Honda | 270 | 2 “ | 2 “ |
| 90261323 | FACGF-23K | Kohler | 728 | 2.5 “ | 2.5 “ |
FACGF-23K engine displacement: Franklin Electric’s current model listing states 728 cc, while the archived series catalog and older ordering table state 725 cc. Confirm the installed Kohler engine identification and serial number before ordering engine components. The FACGF-23K is electric-start equipped; the older catalog specifies that the battery and fuel tank are not included.
FACGF-8: This model appears in earlier Franklin Electric service and replacement-engine references but not in the current four-model product listing. Its specifications and repair-part entries are retained below to help identify existing equipment. Do not assume it is available as a new complete pump.
FACGF Ordering Information and Historical Specifications
The following ordering table is preserved from the older FACGF series literature, including original order numbers, engine descriptions, low-oil shut-off entries, weights, and the catalog-era 725 cc designation for FACGF-23K.
| Model | Suc. / Dis. (NPT) | CC | Engine Description | Order No. | Low Oil Shut-Off | Wt. (lbs) |
|---|---|---|---|---|---|---|
| FACGF-5 | 2 x 2 | 205 | Briggs & Stratton INTEK, with 3 qt. fuel tank | 90261005 | NO | 62 |
| FACGF-5H | 2 x 2 | 160 | Honda, with 4 qt. fuel tank | 90261105 | YES | 62 |
| FACGF-8H | 2 x 2 | 270 | Honda, with 6 qt. fuel tank | 90261108 | YES | 82 |
| FACGF-23K | 2-1/2 x 2-1/2* | 725 | Kohler CH730, electric start | 90261323 | YES | 275 |
FACGF Technical Specifications Table
| Specification | Value |
|---|---|
| Maximum Capacity | 270 GPM |
| Maximum Head | 240 Feet |
| Maximum Working Pressure | 150 PSI |
| Maximum Temperature | 200 degrees F |
| Rotation | Clockwise when viewed from motor end |
| Pipe Connections | NPT |
| Mounting Position | Horizontal |
| Engine Options | Briggs and Stratton, Honda, Kohler |
Choosing the Right FACGF Model
FACGF-5 and FACGF-5H: 2-Inch Gas Engine Pumps
The FACGF-5 uses a 205 cc Briggs & Stratton engine and the FACGF-5H uses a 160 cc Honda engine. Both models are listed with 2-inch suction and 2-inch discharge connections. Compare the required flow and head against the manufacturer’s performance chart rather than choosing solely by engine brand.
FACGF-8H: Honda-Powered 2-Inch Pump
The FACGF-8H uses a 270 cc Honda engine and 2-inch NPT suction and discharge connections. It is a distinct model from the earlier FACGF-8 Briggs & Stratton configuration identified in the service parts documentation.
FACGF-23K: Kohler-Powered 2.5-Inch Pump
The FACGF-23K features a Kohler engine, 2.5-inch suction and discharge connections, and electric starting. Manufacturer documentation lists an approximate pump-unit weight of 275 lb. Confirm battery, fuel tank, engine identification, and installation requirements before procurement.
Where FACGF Centrifugal Pumps Are Used
- Agricultural irrigation: Transferring relatively clean water to field irrigation equipment where engine power is preferred.
- Construction water supply: Providing temporary water transfer at sites without a fixed electrical supply, subject to suction and hydraulic requirements.
- Commercial and municipal applications: Temporary circulation or water transfer with a portable engine-driven pump.
- Mining and light industrial use: Moving compatible water-based liquids in installations that benefit from an engine-driven centrifugal pump.
The FACGF uses an enclosed impeller. It should not be represented as a trash pump or specified for abrasive solids without confirmation of the actual liquid characteristics and manufacturer guidance.
Installation and Priming Requirements
Important: The FACGF is not self-priming. Franklin Electric’s FACGF owner’s manual instructs installers to fit a foot valve at the bottom of the suction line and to fill the pump casing and suction line with water before starting the engine. Running the pump dry may damage the mechanical seal or impeller.
- Place the unit on a firm, level surface near the water source and secure it against movement from vibration.
- Keep the suction hose free of air leaks and kinks; use suction piping and foot-valve sizes at least as large as the pump’s suction connection.
- Confirm the specific model’s suction and discharge dimensions before selecting fittings.
- Follow Franklin Electric’s priming procedure and the engine manufacturer’s operating and maintenance instructions.
- Check liquid compatibility. The manual prohibits pumping flammable fluids.
- Shut down the engine before servicing, and drain the cast iron pump housing for freezing conditions or storage.
For installation instructions and the performance curve, consult the Franklin Electric FACGF manufacturer product and support page.
FACGF Replacement Parts and Exploded Views
Use the exploded views and original model-specific repair table to identify replacement components. Confirm part numbers against the pump model, engine identification, and manufacturing date before placing an order.
FACGF-5, FACGF-5H, FACGF-8 and FACGF-8H Exploded Parts

FACGF-23K Exploded Parts

FACGF Replacement Parts by Model
| Fig. No. | Part Description | Part No. | |||||
|---|---|---|---|---|---|---|---|
| FACGF-5 | FACGF-5H | FACGF-8 | FACGF-8H | FACGF-23K | Materials | ||
| 1 | FACGF Pump Case | 305459001 | 305459003 | Cast Iron, ASTM-A48 CL30 | |||
| 2 | FACGF Impeller | 305459004 | 305459005 | 305459007 | Cast Iron, ASTM-A48 CL30 | ||
| 3 | FACGF Motor Adapter | 305459008 | 305459009 | 305459010 | Cast Iron, ASTM-A48 CL30 | ||
| 12 | FACGF Mechanical Seal Shaft Sleeve | 305458010 | 305459011 | 305459013 | 416 Stainless steel | ||
| 35 | FACGF Shaft Key | N/A | 305456005 | 300 Stainless Steel | |||
| 70 | FACGF Base, Engine Frame | 305459015 | 305459016 | 305459024 | CRS (Low Carbon) | ||
| 76 | FACGF Battery Holder Assembly | N/A | 305457008 | CRS (Low Carbon) | |||
| 77 | FACGF Pump Handle | 305459017 | 305459018 | 305459019 | N/A | CRS (Low Carbon) | |
| 90 | FACGF Mechanical Shaft Seal | 305463116 | 305463043 | Carbon/Ceramic Viton/316SS | |||
| 100 | FACGF Case O-ring / Gasket | 305463117 | 305463118 | EPDM | |||
| 200 | FACGF Engine | See Engines Below | Misc. | ||||
| 500A | FACGF Pipe Plug 1/4″ (4-Pack) | 305463020 | Cad-Plated Steel | ||||
| 500B | FACGF Pipe Plug 1/8″ / 3/8″ (4-Pack) | 305463009 | 305463175 | Cad-Plated Steel | |||
| 503 | FACGF Water Slinger | 305458022 | 305456009 | 305459022 | Neoprene | ||
| 510 | FACGF Impeller Bolt | N/A | 305463119 | 300 Stainless Steel | |||
| 520 | FACGF Impeller Washer | N/A | 305455014 | 300 Stainless Steel | |||
| 531 | FACGF Threaded Stud – Volute (8-Pack) | 305463114 | N/A | 18-8 Stainless Steel | |||
| 530A | FACGF Lockwasher – Volute (8-Pack) | 305463032 | N/A | Zinc Plated Steel | |||
| 530B | FACGF Hex Nut – Volute (8-Pack) | 305463033 | N/A | Zinc Plated Steel | |||
| 530C | FACGF Hex Bolt – Motor/Adapter (4 Req.) | 305463120 | 305463223 | N/A | Zinc Plated Steel | ||
| 530D | FACGF Collar Seal/Washer – Motor/Adapter | 305463107 | 305463092 | N/A | Nylon/Zinc Plated Steel | ||
| 531 | FACGF Threaded Stud – Motor/Adapter (4-Pack) | N/A | 305463093 | Zinc Plated Steel | |||
| 530A | FACGF Lockwasher – Motor/Adapter (8-Pack) | N/A | 305463032 | Zinc Plated Steel | |||
| 530B | FACGF Hex Nut – Motor/Adapter (8-Pack) | N/A | 305463033 | Zinc Plated Steel | |||
| 530C | FACGF Hex Bolt – Volute (12-Pack) | N/A | 305463010 | Zinc Plated Steel | |||
| 530E | FACGF Hex Bolt – Base (4-Pack) | 305463122 | 305463123 | 305463122 | 305463111 | Zinc Plated Steel | |
| 530F | FACGF Washer Base (4-Pack) | 305463109 | Zinc Plated Steel | ||||
| 530G | FACGF Lockwasher – Base (4-Pack) | 305463092 | Zinc Plated Steel | ||||
| 530H | FACGF Hex Nut – Base (4-Pack) | 305463062 | Zinc Plated Steel | ||||
| Not shown | FACGF Spacer – Base (4 Pack) | N/A | 305463192 | N/A | Cast Iron, ASTM-A48 CL30 | ||
Service reference: FACGF-8 and its historical replacement parts remain listed for identification; availability and interchangeability must be confirmed. Parts that span several model columns in the source catalog retain their shared part-number cells above.
FACGF Replacement Engine References
| Fig. No. | Pump Model | Engine Description | Part No. |
|---|---|---|---|
| 200 | FACGF-5 | ENG B/S 12T432-2119-F9 205cc | 201915 |
| FACGF-5H | ENG HONDA GX160UT1TX2 160cc OHV | 202001 | |
| FACGF-8 | ENG B/S 20T232-0125-F1 305cc | 201918 | |
| FACGF-8H | ENG HONDA GX270UTPA2 270cc OHV | 202002 | |
| FACGF-23K | ENG KOHLER CH730-0714-A | 106928101 |
FACGF Pump Dimensions
The following dimensions are reproduced from the original FACGF series table. The dimensional data are for estimating and planning purposes. Verify the actual installed dimensions before fabricating a mounting base or fixed piping.
FACGF-5, FACGF-5H, FACGF-8 and FACGF-8H Dimensional Table
| Model | Suc. / Dis. (NPT) | A | B | C | D | E | F | G | H | J Holes | L | W |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FACGF-5 | 2 x 2 | 11.23 | 4.06 | 10.75 | 4.93 | 3.65 | 4.85 | .063 | 17.18 | .041 | 16.32 | 14.60 |
| FACGF-5H | 11.23 | 4.06 | 10.75 | 4.93 | 3.65 | 4.85 | .063 | 13.92 | .041 | 16.35 | 15.60 | |
| FACGF-8 | 12.64 | 4.06 | 13.50 | 6.33 | 5.87 | 6.39 | 1.75 | 13.44 | .041 | 23.72 | 20.26 | |
| FACGF-8H | 12.68 | 4.06 | 13.50 | 6.37 | 5.87 | 6.38 | 1.75 | 17.71 | .041 | 19.30 | 17.43 |
FACGF-23K Dimension Drawing

For detailed FACGF-23K mounting dimensions and clearances, consult the dimensional drawing above and the Franklin Electric catalog.
FACGF Performance and Pump Selection
Franklin Electric provides performance curves for the FACGF model groups in its series catalog. Use the required flow rate (GPM), total dynamic head (feet), suction lift, and piping losses to select the correct configuration. The catalog maximum of 270 GPM and 240 feet of head should not be interpreted as a single operating point.
When matching an existing unit, provide the FACGF model, engine make, complete engine model or serial number, and any part number visible on the component being replaced.
Frequently Asked Questions About Franklin Electric FACGF Pumps
Is the Franklin Electric FACGF self-priming?
No. Franklin Electric’s owner’s manual explicitly states that FACGF pumps are not self-priming. A foot valve must be installed, and the pump casing and suction line must be filled with water before startup.
What FACGF models are currently shown by Franklin Electric?
The manufacturer lists FACGF-5 (90261005), FACGF-5H (90261105), FACGF-8H (90261108), and FACGF-23K (90261323). The older FACGF-8 appears in archival technical and parts documentation.
How do the FACGF connection sizes differ?
FACGF-5, FACGF-5H and FACGF-8H use 2-inch suction and discharge connections. The FACGF-23K uses 2.5-inch suction and discharge connections.
What is the maximum capacity of the FACGF series?
The published FACGF series limits are up to 270 GPM flow and 240 feet of head, with a maximum working pressure of 150 PSI. These limits are not simultaneous guaranteed operating values.
Which engine is fitted to FACGF-23K?
The FACGF-23K uses a Kohler engine and electric start. The current manufacturer listing identifies 728 cc, while an older catalog states 725 cc. Confirm the physical engine identification before ordering service parts.
Are replacement parts available for older FACGF pumps?
Parts references are provided above for FACGF-5, FACGF-5H, FACGF-8, FACGF-8H and FACGF-23K. Contact Ken’s Distributing Company with your model and part number to verify fit and availability before ordering.
Related Franklin Electric Pumps
- Franklin Electric FNG-23V gas engine centrifugal pump and repair parts
- Franklin Electric FBSGF gas engine self-priming pumps
- Franklin Electric FNSGF gas engine self-priming pumps
- Franklin Electric FMIG gas engine self-priming pumps
- Franklin Electric replacement parts
Request a FACGF Pump or Replacement Parts Quote
Contact Ken’s Distributing Company at 303-699-7845 to confirm current FACGF pump availability, choose a model for your operating conditions, or identify replacement components for an existing unit. Include your model number, required flow and head, and engine identification where possible.
Send us your model number and we will confirm fit, price, and availability.